his paper outlines a methodological toolset for policy decision-making on the choice of multilayered building enve- lopes, focusing on physically measurable dynamic thermal performance and Life Cycle Energy Analysis (LCEA) param- eters. Based on the DSTU EN ISO 13786:2023 Code, the current framework limits key thermal performance parameters to thermal transmittance (U-value), internal areal heat capacity (k1), and the decrement factor (f). The objective function, total energy (Etot), comprises operational energy (Eoper) and embodied energy (Eemb) demands, along with constraints such as assembly mass, width, and U-value. Five multilayered assemblies - Hempcrete, AAC, Porotherm brickwork, Arbolit (wood-chip cement-bonded blocks) and one ICF system were numerically evaluated and analysed in a modelling comparison. Results indicate that only wall B (AAC) demonstrates minimum Etot falls within the constraints range. The study highlights the complexity of satisfying both the thermal performance and energy-efficiency demand with being optimal in both. As well current research provides clear framework for predesign objective decision-making.
Ключові слова
Dynamic thermal performance efficiency; Pareto-frontier; Multilayered assembly; Optimal non-dominated solution; Energy efficiency; Physical parameters