Enhancing the Operation Efficiency of Air conditioning system for Integrated power plant on the base of its monitoring
Остання редакція: 2021-11-22
Анотація
The operation of the ambient air conditioning systems (ACS) is characterized by considerable fluctuations of the heat load in response to the current climatic conditions. This needs the analyses of the efficiency of application of compressors with frequency converters for refrigeration capacity regulation in actual climatic conditions. A new method and approach to analyzing the efficiency of ACS cooling capacity adjusting by using the compressor with changing the rotational speed of the motor as an example has been developed, according to which the overall range of changeable heat loads is divided in two zones: the zone of ambient air processing with considerable fluctuations of the current heat load, that requires effective refrigeration capacity regulation by compressor with frequency converters (from 100% rated refrigeration capacity down to about 50 %) and not adjustable zone of reduced refrigeration capacity below 50 % rated refrigeration capacity of compressor. The magnitudes of threshold refrigeration capacity between both zones are chosen according to the rational value of installed (design) refrigeration capacity on the ACS, required for cooling the ambient air to a target temperature that ensures the maximum annual refrigeration capacity production in actual current climatic conditions. The proposed method and approach to the analysis of the efficiency of the refrigeration capacity regulation of the ACS compressor by distributing the overall range of changes in current heat loads allows to increase the efficiency of utilizing the installed refrigeration capacity in current climatic conditions
Ключові слова
Ambient Air Processing; Stable Heat Load; Changeable Heat Load; Threshold Refrigeration Capacity; Refrigeration Capacity Distribution
Посилання
Marque, R.P., Hacon, D., Tessarollo, A., Parise, J.A.R.: Thermodynamic analysis of trigeneration systems taking into account refrigeration, heating and electricity load demands. Energy and Buildings 42, 2323–2330 (2010).
Ortiga, J., Carles, B.J., Alberto, C.: Operational optimization of a complex trigeneration system connected to a district heating and cooling network. Applied Thermal Engineering 50, 1536–1542 (2013).
Li, Y., Wu, J., Shiochi, S.: Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions. Energy Build. 41, 949–957 (2009).
Повний текст:
PDF